Overview
The RC-PHP-500 is a mains-powered accessible passenger help point that connects people at transport platforms, interchange walkways and public arrival areas to a staffed assistance desk. REDCOAST.LTD supplies the terminal, call-routing integration, Web management platform and maintenance App as one configurable solution. Separate Information and Emergency buttons, an integrated hearing loop and visible call-state indicators help passengers request the appropriate service without using a smartphone. The compact wall or pedestal format suits locations with existing electricity and network infrastructure; the specifications below describe a proposed build-to-order configuration, with performance targets to be confirmed through prototype qualification and the project datasheet.
Key Features
- Two clearly differentiated call paths: Dedicated Information and Emergency buttons route to separate operator groups, with up to four sequential destinations per button and configurable escalation timers.
- Integrated assistive listening: A local induction loop delivers the operator's speech to compatible hearing aids with an enabled telecoil; installation includes verification at the marked listening position.
- Accessible physical controls: Two 45 mm buttons, a maximum 10 N design actuation force, tactile identifiers and Braille label options accompany illuminated symbols that communicate more than color alone.
- Hands-free conversation: Echo cancellation, microphone noise reduction and a 5 W Class-D amplifier support two-way speech, with commissioning adjustments for reverberation and passing traffic.
- Optional visual context: A 1080p camera gives the operator a view of the caller and immediate surroundings, with configurable framing and privacy masking.
- Supervised operation: Network registration, button faults, enclosure tampering and scheduled acoustic checks feed a maintenance dashboard and assigned service tickets.
- Local call continuity: Stored routing and a reachable on-site SIP server allow calling during loss of the management cloud; alternate servers and destinations follow the agreed operating policy.
- Project-specific hardware: REDCOAST.LTD can develop custom main, audio, loop-driver and interface PCBs to accommodate existing cabinets, operator workflows and infrastructure connections.
Technical Architecture
The terminal contains a processor-based communications board, an independent supervisory microcontroller, an audio codec and amplifier board, an induction-loop driver, protected input/output circuits and an isolated power stage. REDCOAST.LTD designs the board-level hardware around the selected processor and communications components rather than developing semiconductor chips. The loop cassette sits behind a non-metallic fascia window so its magnetic field is not enclosed by a continuous steel plate. A replaceable camera module and separate button assemblies simplify configuration and servicing.
A button press generates a station-identified SIP call using its assigned priority and destination list. The station presents calling, connected or unavailable states through distinct icons and locally stored prompts. A busy or unanswered destination advances according to the configured timeout; a call is shown as connected only after the remote endpoint answers. Emergency calls receive routing priority, but operator staffing and concurrent-call capacity determine actual response. The system forwards requests to people; it does not make train-movement or traction-power decisions.
Voice and optional video remain on the configured communications network. The Web platform receives health records, call metadata, configuration revisions and maintenance events, while the App provides technicians with asset location, fault history and work orders. Cloud connectivity is not required for a local SIP call when the endpoint, network and on-site server remain powered and reachable. Remote firmware packages use signature verification, and a rollback image supports recovery from an unsuccessful update. Audio or video recording, if purchased, is managed by the designated server with access controls and a documented retention policy.
Connectivity & Power
The reference installation uses a mains-fed IEEE 802.3at Type 2 PoE+ switch, combining power and 10/100 Ethernet in one cable. A copper Ethernet channel is limited to 100 m; longer routes use fiber to a nearby powered switch. The station design budget is 7 W idle, 12–18 W during a typical call and 22 W maximum without the optional heater, including the selected camera and loop. This fits below the 25.5 W available to a Type 2 powered device; the switch-side power allocation and cable loss must also be budgeted. Texas Instruments PoE power guidance
Where only mains and a data connection are available, a separately enclosed AC 100–240 V, 50/60 Hz supply provides isolated 24 V DC. The optional 8 W anti-condensation heater requires this local DC configuration, raising the station maximum to 30 W; it is not included in the PoE+ configuration. An external LTE router can provide IP backhaul where wired data is unavailable, subject to coverage, operator policy and an additional power allowance. Ethernet and cellular backhaul carry live voice; low-bandwidth sensor networks are not used for the conversation.
Service continuity depends on the power and availability of the entire path: terminal, switch, router, SIP server and answering console. A site's existing essential-power distribution can supply these elements. Loss of mains at an unprotected installation stops the station, and a cellular path change can interrupt an active call. This product configuration uses grid electricity and contains no solar generation.
Protection & Reliability
The enclosure design targets IP65 ingress protection and IK10 impact resistance for the complete qualified assembly, including the selected camera window and controls. Sealed cable entries, acoustic membranes, captive security screws and a tamper switch address outdoor exposure and unauthorized opening. The specified operating target is -20 to +55 °C ambient, with direct solar heating included in the project thermal review rather than assuming internal temperatures equal ambient air.
The carbon-steel rear housing, mounting brackets and optional pedestal receive hot-dip galvanizing followed by a smooth matte powder-coated finish. Exposed coastal locations can use a separately specified fluorocarbon topcoat system, with edge treatment and dissimilar-metal isolation included in the fabrication plan. Salt exposure, sand abrasion and cleaning chemicals require a site-specific materials review; a short corrosion test is not a service-life prediction. Pedestal anchors and foundations are sized for local wind loads and the actual ground conditions.
Replaceable microphones, speakers, gaskets and button modules support maintenance without replacing the whole station. Scheduled acoustic tests can identify major audio-path faults, while human test calls remain necessary to assess intelligibility and operator response. Warranty duration, spare-parts availability and firmware support are defined in the supply contract against the agreed environment and maintenance schedule.
Application Scenarios
Light-rail and tram platforms. Install compact help points beside accessible waiting areas, away from platform-edge hazards. Information calls reach passenger services, while urgent requests reach the designated incident desk with the platform identifier already attached.
Bus rapid transit interchanges. Use the existing station power and communications network to connect passengers to a central service team. Separate call queues help keep routine route questions from occupying the same answering workflow as urgent assistance requests.
Ferry terminal boarding areas. Place sealed wall-mounted units near sheltered waiting zones and accessible boarding routes. A hearing loop and optional camera help staff understand boarding-assistance requests, while the coating package is selected for the actual salt exposure.
Park-and-ride transfer walkways. Position pedestal units where passengers move between parking and transit facilities. A mapped asset identifier gives staff a precise meeting point even when the caller cannot describe the surrounding area.
Hospital and campus shuttle hubs. Provide a physical contact point for visitors who need mobility assistance, directions or support after normal reception hours. Local SIP routing can reach the staffed security or transport desk without requiring a personal phone or mobile application.
Case-style Examples
The following are illustrative configuration studies, not completed customer installations or measured performance claims.
Unstaffed platform assistance upgrade. An operator manages eight platforms from one control room and needs distinct routes for travel information and urgent requests. A proposed installation places two RC-PHP-500 terminals on each platform, connects them to existing PoE+ switches, enables hearing loops and assigns separate operator groups with a 20-second unanswered-call escalation. The intended operational result is a consistent contact method with exact platform identification; acceptance checks cover every call route, concurrent calls, listening positions and cloud-disconnection behavior.
Accessible transfer-hub refurbishment. A facility needs six help points along a route connecting a parking structure, shuttle stop and terminal entrance. The proposed configuration uses shallow wall units where space permits and coated pedestals in open areas, with optional cameras at selected locations and fiber-linked local network cabinets. The expected benefit is a clearly identifiable assistance route and a shared maintenance view; commissioning confirms reach, pedestrian clearance, call audibility and service-desk procedures before public use.
Customization & Selection Guide
Start with the passenger journey and answering arrangement. Identify who answers each button, staffed hours, overflow destinations and the maximum number of simultaneous calls. A simple two-button audio station is appropriate where voice and a mapped location provide enough context. Add the camera when visual assessment helps the operator, and confirm that the receiving console can display the chosen stream.
Next, survey reach, wheelchair approach, ambient noise, magnetic interference and cable routes. The suggested button-center range is 1,000–1,100 mm above finished ground, subject to the applicable accessibility rules and the actual approach geometry. Braille language, pictograms and audible prompts must match the agreed passenger interface. Hearing-loop coverage is a local listening position, not a whole-platform broadcast area; its field strength and background magnetic noise require measurement after installation.
For existing network infrastructure, select PoE+ and verify the available switch power budget. Choose the separate 24 V supply when anti-condensation heating is required, and use fiber between separated buildings or long platform sections. A cost comparison should include terminals, civil works, network equipment, SIP capacity, integration, testing and ongoing support. The reference management package covers 128 terminals and eight simultaneous calls; larger or redundant deployments require a separately sized server and answering arrangement.
Deployment & After-sales
Installation begins with a site drawing, enclosure selection, station naming convention and approved call-routing matrix. The delivery package can include mounting drawings, cable schedules, a network addressing plan, hardware revision records, interface documentation and a factory acceptance procedure. Prototype, compliance testing and production milestones are scheduled after requirements and interfaces are frozen; repeat units can reuse an approved hardware revision, while a new PCB or enclosure introduces additional engineering and qualification work.
On site, technicians verify mounting, protective bonding where applicable, sealed entries, network access and both call buttons. Acceptance also exercises busy destinations, unanswered calls, server unavailability, microphone and speaker faults, loop performance and restored connectivity. REDCOAST.LTD can provide remote commissioning assistance, technician training, replaceable assemblies and agreed support escalation. Software updates are scheduled around operating hours, and maintenance records link each unit to its installed hardware and firmware revision.
Standards & Compliance
The compliance plan is selected for the destination and installation. The following references define relevant assessment areas; they are not a claim that the proposed RC-PHP-500 already holds certification.
- Enclosure protection: Use IEC 60529 for the IP65 target and IEC 62262 for the IK10 target. The assessment must cover the assembled terminal and selected mounting arrangement. IEC 60529, IEC 62262 consolidated edition
- Assistive listening: IEC 60118-4:2014 with Amendment 1:2017 provides the hearing-loop performance framework. Installation testing addresses magnetic field strength, frequency response and background interference at the intended listening positions. IEC hearing-loop standard amendment
- Electrical safety: IEC 62368-1:2023, including its 2025 corrected version, is a relevant safety reference for audio/video and communications equipment. The conformity plan must identify the edition adopted in the destination market. IEC 62368-1
- Railway electromagnetic compatibility: EN 50121-4:2016+A1:2019 is considered where the equipment location and connected ports fall within its railway signalling and telecommunications scope. Project-specific tests and operator acceptance remain necessary. BSI standard record
- Accessible installation: Reach ranges, approach space and operating force must be checked against the applicable local requirements. Where ADA requirements apply, Sections 308 and 309 provide relevant criteria; specifying accessible controls alone does not establish whole-site compliance. Official ADA accessibility standards
Current category references include transport help points with built-in hearing loops and PoE+, and dual-button IP stations for ordinary and emergency calls. These support the configuration approach, not this model's performance or certification. Zenitel ECP-C1 specification, Aiphone 2025 emergency-solutions brochure
Why REDCOAST.LTD
REDCOAST.LTD combines outdoor hardware, embedded software, Web management and mobile maintenance tools within one project scope. Its in-house PCB and board-level design capability allows the terminal dimensions, audio electronics, induction-loop driver, isolated I/O and power management to be engineered around the installation. Customers can align hardware revisions, call workflows and platform interfaces through one delivery team, with integration responsibilities and acceptance criteria established before manufacture.
Send REDCOAST.LTD your site layout, station quantities, accessibility requirements and existing communications details to request a tailored RC-PHP-500 configuration and quotation.
Specifications
Passenger Interface & Accessibility
- Call controls
- 2 illuminated buttons: Information and Emergency; 45 mm diameter each
- Button actuation force target
- 10 maximum N
- Visual status indicators
- 4 distinct icons: Calling, Connected, Unavailable and Hearing Loop
- Suggested button-center height
- 1000–1100 above finished ground; subject to approved accessibility layout mm
- Hearing-loop amplifier passband target
- 100–5000; ±3 dB electronic response before installation effects Hz
- Hearing-loop driver current limit
- 2 RMS maximum; matched local loop cassette A
Audio & Optional Video
- Audio codecs
- G.711 A-law/μ-law; G.722
- Speaker amplifier
- 5 rated output into 8 ohms; Class D W
- Sound-pressure design range
- 70–90 adjustable at 1 m, on axis; reference test signal dB(A)
- Microphone arrangement
- 2 digital microphones with echo cancellation and noise reduction
- Optional camera format
- 1920 × 1080 at up to 15 fps; 100° nominal horizontal field of view
- Optional video stream
- H.264 over RTSP; 1–3 configured bitrate Mbit/s
Grid Power
- Upstream mains input
- AC 100–240, 50/60 Hz; through selected external PSU or PoE+ switch V
- PoE input
- IEEE 802.3at Type 2, Class 4; heater excluded
- Alternative station DC input
- 24 nominal; 21.6–26.4 operating range V DC
- Idle station consumption target
- 7; heater off W
- Typical active-call consumption target
- 12–18; heater off W
- Maximum station input budget
- 22 without heater; 30 with optional 8 W heater on local DC supply W
- External local PSU option
- 24 V DC, 2 A, 48 W rated output; separately enclosed and isolated
Network & Integration
- Ethernet interface
- 1 × RJ45, 10/100BASE-TX
- Copper Ethernet channel limit
- 100 including patch leads; fiber extension through external equipment m
- SIP registrar configuration
- 2 server addresses: primary and secondary
- Call routing
- 4 sequential destinations per button; 10–60 s unanswered-call timeout
- Communications protocols
- SIP over TLS, SRTP, HTTPS, MQTT over TLS, SNMPv3 and NTP
- External I/O
- 2 dry-contact inputs; 2 relay outputs rated 30 V DC, 1 A resistive; dedicated tamper input
Edge Supervision & Management
- Nonvolatile storage
- 8 GB
- Local event buffer
- 50000 timestamped metadata records; excludes audio/video recording records
- Health-report interval
- 30–300 configurable s
- Scheduled acoustic-test interval
- 6–168 configurable; tests run only when idle h
- Reference management package
- 128 terminals; 8 simultaneous calls across provisioned answering endpoints
- Reference server allocation
- 4 vCPU, 8 GB RAM, 80 GB storage; excludes media recording and redundancy
- Firmware maintenance
- Signed update packages; 2 boot images for update and rollback
Mechanical & Installation
- Wall terminal dimensions
- 360 × 200 × 95; H × W × D mm
- Wall terminal mass target
- 4.5; excluding mounting accessories kg
- Optional pedestal height
- 1300 overall; button positions set by approved layout mm
- Housing construction
- 1.5 mm steel rear enclosure, 2 mm steel front panel, non-metallic loop window
- Protective finish
- Hot-dip galvanized steel with smooth matte powder coating; RAL 7016 or RAL 9016
- Mounting formats
- Surface wall mount; flush-mount adapter; anchored floor pedestal
Environmental & Protection Targets
- Ingress-protection target
- IP65; complete assembly qualification required
- Mechanical-impact target
- IK10, 20 J; includes selected controls and windows in qualification
- Operating ambient target
- -20 to +55; solar heating assessed separately °C
- Storage temperature target
- -30 to +70 °C
- Relative humidity target
- 5–95, non-condensing inside enclosure % RH
- Optional anti-condensation heater
- 8; local 24 V DC supply only; does not extend the stated ambient rating W
Capabilities — configurable per project
Specifications are tailored to each project — the options below show what we can support.
Terminal Format
- Surface-mounted wall terminal
- Flush-mounted wall terminal
- Floor-mounted pedestrian pedestal
Passenger Interface
- Dual-button audio with hearing loop
- Dual-button audio/video with hearing loop
- Project-language tactile labels, Braille and audible prompts
Network Architecture
- On-site SIP server over Ethernet
- Central SIP service over private WAN
- External LTE IP router with separate power allowance
Grid Power Delivery
- IEEE 802.3at PoE+
- Grid-fed isolated 24 V DC
- Grid-fed 24 V DC with 8 W anti-condensation heater
Exterior Finish
- RAL 7016 matte powder coating over galvanizing
- RAL 9016 matte powder coating over galvanizing
- Fluorocarbon topcoat over a qualified coastal corrosion-protection system
Related solution guidance
Power and Connectivity
How to choose power, battery, solar, NB-IoT, LTE, LoRaWAN, gateways and monitoring strategy for outdoor IoT infrastructure.
Airports and Hubs
IoT infrastructure for transport hubs: parking guidance, road safety, outdoor lighting, signage, monitoring and operational dashboards.
Industrial Parks
Industrial park IoT for lighting, access areas, environmental monitoring, energy visibility, parking and maintenance operations.
Frequently Asked Questions
What is an accessible passenger help point used for?
It gives passengers a fixed location for contacting a staffed assistance desk without a smartphone. The RC-PHP-500 combines separate Information and Emergency buttons with hands-free speech, visual call status and a hearing loop. Typical locations include transit platforms, interchange walkways, ferry terminals and shuttle hubs.
How is the RC-PHP-500 powered, and does it work during a power outage?
The reference configuration receives power from a mains-fed PoE+ switch, with a 22 W maximum station design budget and no heater. A separate AC 100–240 V supply can provide 24 V DC for installations requiring the optional heater, increasing the station budget to 30 W. Operation during a mains outage requires the site's essential-power system to maintain the terminal, network, SIP server and answering equipment; an unprotected station stops when power is lost.
Will the hearing loop work with every hearing aid?
The loop serves hearing aids or compatible receivers with an enabled telecoil, often identified as a T or MT setting. It does not automatically connect to every hearing aid or Bluetooth device. The installation must be measured at the intended seated and standing listening positions because metalwork and magnetic interference can change performance.
Can the help point connect to an existing SIP telephone system and video platform?
The proposed interface uses SIP with G.711 or G.722 audio, and the optional camera provides an H.264 RTSP stream. Integration requires checking registration, authentication, encryption, call transfer, routing and video display against the actual server and console. An interface test is included in project acceptance rather than assuming compatibility with every PBX or video platform.
Can passengers make calls if the management cloud is unavailable?
Yes, provided the terminal, local network, on-site SIP server and answering endpoint remain powered and reachable. Stored routing supports this local call path while health records can be buffered for later upload. A deployment that routes calls only through a remote service also depends on its WAN connection and that service's availability.
Can the terminal be installed on exposed railway or tram platforms?
The reference design targets IP65, IK10 and -20 to +55 °C ambient, with qualification required for the selected assembly. The site review also covers direct sun, corrosion, wind loading of pedestals, cable protection, accessibility and railway electromagnetic compatibility. Product targets and a standards list do not replace prototype tests or the transport operator's installation acceptance.
What can REDCOAST.LTD customize, and what is needed for a quotation?
REDCOAST.LTD can develop custom PCBs, audio and hearing-loop electronics, I/O, enclosure dimensions, passenger labels, firmware and Web/App workflows. Provide station quantities, mounting drawings, climate and exposure conditions, accessibility requirements, network details and the intended answering arrangements. The quotation then separates engineering, prototype qualification, production hardware, software integration and support.