Overview
The RC-CDS-700 is a grid-powered controlled drainage and subirrigation station from REDCOAST.LTD for farms, agricultural estates, irrigation authorities, and drainage contractors managing buried field-drain networks. It combines a motorized outlet gate, water-table monitoring, controlled supplemental-water admission, a Web management platform, and a mobile App to coordinate water retention, drainage, and irrigation through one operating interface. Its purpose is to replace repeated manual outlet adjustments with measured, scheduled control while keeping root-zone waterlogging and unnecessary water admission visible to operators. The reference installation serves one hydraulically independent field zone beside an existing mains-powered pump house or drainage hub; it requires a site-designed drainage network and an approved water source. The specifications describe a made-to-order reference design, with final component selections, environmental ratings, and acceptance criteria confirmed during project engineering.
Key Features
- Three coordinated water-management modes: Free drainage, controlled retention, and supplemental subirrigation use separate operating limits, with a local service mode for maintenance.
- Field-level feedback: One chamber sensor and up to four observation-well sensors distinguish outlet conditions from the groundwater conditions experienced across the field.
- Measured water admission: A flow-meter input, maximum fill duration, and daily volume allowance provide independent limits on supplemental irrigation.
- Local operation without cloud access: Stored schedules, sensor checks, gate positioning, and pump-permission logic continue during a communications outage.
- Purpose-designed electronics: REDCOAST.LTD develops the mixed-signal acquisition PCB, actuator-control PCB, protected power distribution, and firmware around the project's actual instruments.
- Practical actuator diagnostics: Position feedback, travel timeout, motor-current monitoring, and limit inputs help identify a stalled gate or failed linkage.
- Traceable farm operations: Water levels, operating modes, admitted volume, alarms, and operator changes appear together in the Web platform and mobile App.
- Retrofit-oriented delivery: Chamber adapters, terminal schedules, pump-starter interfaces, and installation drawings are specified for the existing drainage infrastructure.
Technical Architecture
The station has three physical assemblies: an above-ground electrical cabinet, a drainage control chamber with a motorized slide gate, and distributed field instruments. The cabinet contains an isolated AC/DC supply, a controller with eight 4–20 mA inputs, twelve digital inputs, two RS-485 interfaces, and protected outputs. The reference sensor package uses one vented hydrostatic level transmitter in the chamber and four in screened observation wells. Optional soil-moisture and conductivity instruments connect through remaining analog channels or Modbus. A separate metered inlet admits supplemental water into the field-side chamber through an engineered hydraulic connection; the downstream drainage gate controls discharge.
The controller compares validated readings against a seasonal operating recipe. In retention mode, it regulates discharge to maintain the agreed chamber-level band while checking field-well limits. In subirrigation mode, it enables an external pump starter and a normally closed inlet valve only when the source-water permissive, valid level measurements, flow limits, and field high-water limits permit filling. Opening the drainage gate and admitting water are normally interlocked to avoid pumping directly to the outfall. Minimum dwell times and configurable hysteresis reduce actuator cycling. Sensor disagreement, excessive fill duration, or unexpected flow inhibits further admission and creates an alarm; a separate high-level switch also interrupts the fill-permission circuit.
The local controller timestamps measurements and events before uploading them to the platform. Users can compare observation wells, inspect gate position, approve seasonal recipes, and export CSV records or retrieve data through an authenticated API. A chamber reading is never presented as proof that the entire field has reached the same water level. Cloud analytics can highlight persistent differences, but field measurements and hydraulic response tests determine the operating limits. Published research on automatic controlled drainage with subirrigation supports evaluating dynamic control, while showing that water demand depends strongly on site conditions; its modeled savings are not RC-CDS-700 performance guarantees. Wageningen University & Research, 2024.
Connectivity & Power
The reference station uses AC 100–240 V, 50/60 Hz from an existing farm or drainage-facility supply. An isolated 24 V DC bus powers the controller, instruments, inlet-valve coil, and intermittent gate actuator. Typical monitoring consumption is a design allowance of 15–30 W; the complete cabinet is budgeted at a maximum of 250 W with actuator movement and the optional 50 W anti-condensation heater. External irrigation pumps have their own electrical feeders, motor protection, and starters, and their power is excluded from these figures.
Ethernet is appropriate beside a connected pump house. LTE Cat 1 provides an alternative where cellular coverage is available, with modem bands and operator approval selected for the installation country. Isolated RS-485 carries local Modbus instrument traffic; long exposed field runs require an engineered cable, grounding, and surge-protection arrangement. The reference logger retains at least 90 days of one-minute records for 32 scalar channels, then uploads queued data after reconnection. This configuration includes neither photovoltaic equipment nor an operating backup battery. Loss of mains stops active control and live telemetry; the platform can identify a missed heartbeat.
Protection & Reliability
The cabinet design targets IP66 with the door closed and all specified glands fitted. Its hot-dip-galvanized steel substrate receives a smooth matte powder-coated topcoat; stainless fasteners, sealed connectors, and replaceable gland plates simplify maintenance. The level probes are specified for continuous immersion, while the actuator and electrical cabinet remain above the site's design flood level. The reference ambient range is -20 to +55 °C, subject to assembled-system thermal validation and actuator derating; the water-contact components operate in liquid water from +1 to +40 °C.
Coastal sites require a coating and connector package selected for local salt exposure. Dust exposure, solar heating, cabinet shading, and mounting-anchor loads are reviewed separately, and neither IP66 nor a salt-spray test establishes a universal service life or wind rating. A shaded installation or ventilated sunshield may be necessary where direct sun would push internal temperatures above component limits.
During a power failure, the self-locking gate remains at its last position, the inlet valve closes, and pump permission drops out. A separately sized passive overflow or bypass is therefore a mandatory part of the hydraulic installation; its discharge route and capacity must remain effective with the gate closed and power unavailable. Seasonal maintenance includes exercising the gate, removing sediment, checking probe vent desiccants, inspecting seals, and testing the independent high-level shutdown. Warranty scope, spare-part availability, and maintenance responsibilities are defined in the project supply agreement.
Application Scenarios
Tile-drained arable fields
At a field outlet near an energized pump house, the station adjusts drainage operation around planting, crop development, and harvest access. Observation wells help operators assess whether retaining water at the outlet is affecting the intended parts of the field.
Agricultural estates with supplemental water
An estate with a suitable buried drainage network and an approved freshwater source can add measured water through the field-side chamber during dry periods. Pump permission and volume limits coordinate this operation with source availability and field high-water limits.
Irrigation-authority demonstration plots
Authorities can equip independent trial plots to compare manual management with scheduled, monitored operation. Logged water admission and groundwater response provide evidence for expansion decisions without assuming a predetermined yield or water-saving result.
Existing drainage lift-station sites
Where field drains already converge near a mains-powered lift station, the controller can exchange permissive and fault signals with the existing pump controls. The hydraulic design must preserve the lift station's drainage duty and provide a defined response to high downstream water levels.
Seed-production and research farms
Research teams can apply different approved seasonal water-level recipes to separate hydraulic zones. Timestamped settings and sensor records make treatment changes traceable, while the agronomist retains control of acceptable root-zone conditions.
Case-style Examples
The following are illustrative engineering configurations, not completed customer installations or measured performance claims.
Existing field-outlet retrofit: A farm wants to reduce manual outlet visits while retaining the option to release drainage before machinery enters the field. A reference configuration combines a 250 mm drain connection, one motorized gate, four observation wells, and Ethernet from the adjacent pump house. The resulting workflow lets staff change an approved drainage recipe remotely, inspect field response, and verify gate movement; the field trial establishes whether the selected retention levels are agronomically useful.
Supplemental-water integration: An agricultural estate has a freshwater reservoir, an existing pump starter, and a drainage network confirmed suitable for subirrigation. Its configuration adds a pulse-output flow meter, a normally closed inlet valve, source-level permission, and LTE backhaul. The commissioning outcome is a bounded filling sequence that stops on excessive level, elapsed time, or admitted volume, with water-use records available for subsequent seasonal comparison.
Multiple-zone pilot: A public irrigation project divides a gently varying site into three independently controllable hydraulic zones. Each zone receives its own station and surveyed observation wells, while a shared dashboard displays readings against a common elevation datum. Operators can evaluate different settings without treating the whole site as one uniform groundwater reservoir.
Customization & Selection Guide
Begin with the drainage layout and an elevation survey. Provide pipe sizes, invert levels, outfall tailwater conditions, soil hydraulic properties, crop rooting requirements, and the location of neighboring drains. The feasibility review must establish where retained water can spread and whether raising the water table could affect adjacent land. Existing drainage systems do not automatically provide adequate irrigation distribution; lateral spacing and soil properties may require changes before subirrigation is practical. NC State Extension operating guidance.
For a lower-cost first stage, select drainage and retention control with two field wells and omit the supplemental-water assembly. For a complete drainage/subirrigation package, specify four wells, a source-water permissive, a metered inlet, and the pump-starter interface. Optional soil-moisture or conductivity measurements add context, but do not replace measured groundwater levels or a salinity-management plan. Water quality must be compatible with the crop, soil, pipework, and permitted use.
Select gate size from the required drainage capacity and available head, including submerged outfall conditions. The reference envelope covers 160–400 mm drain connections and up to 1.0 m differential water head; it does not establish a universal flow rate or hectares-per-station figure. Actuator force, stroke, duty cycle, and linkage geometry are checked together. A field with multiple elevations or poorly connected drainage branches may need several independent stations even when its total area is small.
Deployment & After-sales
Deployment starts with a hydraulic survey and an agreed input/output schedule. Civil works install the chamber, passive overflow, observation wells, and protected cable routes before electrical commissioning. Probe elevations are surveyed to a common datum, vent tubes terminate in dry protected locations, and the cabinet mounts above the design flood elevation with clear maintenance access. The commissioning team checks field response rather than assuming chamber and well levels move together.
Factory acceptance covers signal scaling, actuator feedback, interlocks, communications loss, and restart behavior. Site acceptance includes measured gate travel, inlet shutdown, a simulated high-level event, power-loss behavior, and verification of the passive drainage route. The delivery programme separates survey and design approval, any new PCB development, prototype verification, assembly, and site works; the quotation identifies lead times for the actual scope. After-sales deliverables include wiring drawings, configuration backups, an alarm register, operating instructions, remote diagnostic support, and a project-specific spare-parts list.
Standards & Compliance
The project test plan uses IEC 60529 for enclosure ingress protection, IEC 61010-2-201:2024 together with its referenced IEC 61010-1 requirements for applicable control-equipment safety, and IEC 61326-1:2020 for applicable measurement-and-control EMC assessment. These are engineering and verification references, not claims that this concept model already holds certification. Final market-access documentation, radio approvals, applicable CE requirements, and RoHS evidence are determined for the supplied configuration.
Agricultural drainage criteria remain site-specific. NRCS Drainage Water Management practice guidance provides a useful reference framework, while explicitly directing designers to locally applicable technical guidance. It is not a global product certification, and water admission, abstraction, discharge, and neighboring-property effects require their own project review.
Commercial precedent includes remotely managed field-drainage structures described in Agri Drain's February 2026 product update. Component feasibility is supported by published WIKA hydrostatic sensor specifications and LINAK actuator specifications. These sources establish available technology classes; they do not imply supplier endorsement or mandate those brands in the final bill of materials.
Why REDCOAST.LTD
REDCOAST.LTD delivers the complete control solution: field hardware, embedded firmware, Web management, mobile App, and the interfaces needed by the project's existing infrastructure. Its in-house hardware capability includes designing new PCBs and board-level electronics for sensor excitation and acquisition, actuator control, protected power distribution, and industrial communications. That makes it possible to change channel counts, connectors, diagnostics, and operating sequences around a verified project requirement instead of forcing every installation into the same controller layout. Hydraulic civil works and agronomic settings are coordinated with the relevant project specialists so that electrical automation serves a workable field-water strategy.
Contact REDCOAST.LTD with your drainage layout, field elevations, crop requirements, water-source details, and available mains supply to request a tailored RC-CDS-700 configuration and quotation.
Specifications
Hydraulics & Actuation
- Independent hydraulic zones
- 1 per station zone
- Nominal drain connection options
- 160 / 200 / 250 / 315 / 400 mm
- Maximum differential head, reference design
- 1.0; non-pressurized drainage service m water
- Gate actuator rated thrust
- 2500; final linkage and gate load verified per project N
- Actuator stroke options
- 200 / 300 / 450 mm
- Actuator electrical rating
- 24 V DC; up to 4 A
- Gate actuator duty budget
- 10% per 60 min; maximum 180 s continuous movement at +5 to +40 °C; derating outside this range
Water-Level & Field Sensing
- Reference level-sensor package
- 1 chamber sensor + 4 observation-well sensors
- Hydrostatic measurement spans
- 0–2.5 / 0–5.0 m water
- Selected transmitter reference accuracy
- ±0.25% of full scale at +20 °C; installation and thermal errors additional
- Level signal interface
- 4–20 mA, two-wire, vented gauge pressure
- Control sampling interval
- 1 s
- Optional soil-moisture measurement range
- 0–60; soil-specific calibration required for accuracy % VWC
- Optional water-conductivity range
- 0–20; temperature compensation referenced to 25 °C mS/cm
Control & Field I/O
- Analog inputs
- 8 × 4–20 mA; 16-bit conversion
- Digital inputs
- 12; including 2 pulse-capable inputs, maximum 100 Hz each
- Relay outputs
- 4 dry contacts; 2 A at 24 V DC resistive load; external motor starters required
- Operating modes
- Free drainage / Controlled retention / Subirrigation / Local service
- Configurable level hysteresis
- 0.05–0.30 m
- Minimum gate-command dwell setting
- 60–900; subject to actuator duty limit s
- Maximum continuous filling timer setting
- 1–720; constrained by high-level and volume limits min
Mains Power
- AC input voltage
- 100–240, single-phase V AC
- Input frequency
- 50 / 60 Hz
- Internal power supply rating
- 24 V DC, 10 A; 240 W rated output
- Typical monitoring design allowance
- 15–30; actuator and heater inactive W
- Maximum station input design budget
- 250; includes actuator and optional heater, excludes external pumps W
- Optional anti-condensation heater
- 50, thermostatically controlled W
Connectivity & Data
- Ethernet interface
- 1 × 10/100BASE-T
- Cellular backhaul option
- LTE Cat 1; country-appropriate bands and operator configuration
- Local serial interfaces
- 2 × isolated RS-485; Modbus RTU; 9600–115200 bit/s
- Application interfaces
- MQTT over TLS / HTTPS REST API / CSV export
- Telemetry upload interval
- 1–60; configurable min
- Local storage
- 16 GB
- Local record-retention target
- At least 90 days at 1-minute intervals for 32 scalar channels
Protection & Construction Targets
- Cabinet ingress protection target
- IP66; closed door and specified sealed cable entries
- Submersible probe protection requirement
- IP68; minimum 5 m continuous immersion, with dry vent termination
- External actuator protection requirement
- IP66 during movement; installed above design flood level
- Ambient operating design range
- -20 to +55; actuator derating and enclosure thermal validation apply °C
- Water-contact operating range
- +1 to +40; no operation in frozen water °C
- Reference cabinet dimensions
- 600 × 500 × 250, H × W × D; excluding plinth and sunshield mm
- Cabinet material and finish
- 1.5 mm steel; hot-dip-galvanized base with smooth matte powder coating, RAL 7035 or RAL 7016
Capabilities — configurable per project
Specifications are tailored to each project — the options below show what we can support.
Hydraulic package
- Drainage and retention retrofit
- Drainage plus metered subirrigation
- Existing lift-station control interface
Field instrumentation
- Chamber plus 2 observation wells
- Chamber plus 4 observation wells
- Add soil-moisture and water-conductivity instruments
Backhaul and platform
- Ethernet with hosted platform
- LTE Cat 1 with hosted platform
- Ethernet with private-server deployment
Environmental package
- Standard outdoor coated-steel cabinet
- Coastal coating and sealed-connector package
- Sunshield and thermal-monitoring package
Hardware customization
- New PCB with project-specific I/O allocation
- Actuator interface with analog position feedback
- Actuator interface with Modbus position feedback
Related solution guidance
Environmental Monitoring
Deploy environmental monitoring stations with sensors, solar power, gateways, dashboards, alarms and data integration for city and industrial sites.
Solar IoT Guide
A design guide for solar-powered outdoor IoT: load calculation, battery autonomy, low-power firmware, telemetry and maintenance planning.
Street Lighting Guide
A practical guide to choosing smart street lighting controllers, connectivity, platform features, dimming logic and acceptance tests.
Frequently Asked Questions
What is the difference between controlled drainage and subirrigation?
Controlled drainage restricts an outlet to retain water already present in the field drainage system. Subirrigation introduces additional water into a suitable buried drainage network to raise the water table. The RC-CDS-700 reference design coordinates both functions, but supplemental irrigation requires a suitable water source, hydraulic layout, and operating permission.
Can this station convert any existing tile-drained field into a subirrigation system?
No. Feasibility depends on field elevations, lateral spacing, soil permeability, restrictive layers, crop requirements, and available water. A drainage network may retain water successfully yet distribute supplemental water poorly, so a survey and hydraulic assessment come before equipment sizing.
Does the RC-CDS-700 need solar panels or a separate power supply for the irrigation pump?
The reference station uses AC 100–240 V from an existing mains connection and includes no solar panel or operating backup battery. Its 250 W maximum input design budget covers station electronics, the gate actuator, and the optional heater. Irrigation pumps use separately sized feeders, starters, and motor protection; the station provides control permissions rather than motor power.
What happens if the internet connection or mains power fails?
During an internet outage, local control continues using stored settings and valid sensor inputs, and records are queued for later upload. During a mains outage, active monitoring stops, the inlet valve closes, pump permission drops out, and the gate remains at its last position. A properly sized passive overflow or bypass is therefore required independently of the controller.
How much land can one controlled drainage station manage?
One station controls one hydraulically independent zone, with a reference drain-connection range of 160–400 mm. Area cannot be calculated from pipe diameter alone because drainage capacity, elevations, soil properties, and outfall conditions also matter. A hydraulic survey determines whether one field needs one station or several separate zones.
Can REDCOAST.LTD customize the PCB, sensors, and farm-management integration?
Yes. REDCOAST.LTD can design new acquisition, actuator-control, and power-distribution PCBs around the agreed sensor and interface requirements. The complete project can include embedded firmware, a Web platform, a mobile App, and authenticated data interfaces. Hardware changes require an updated specification and verification plan.
Are the stated ratings certified, and are water savings guaranteed?
The published figures define a configurable reference design, not an existing certificate or completed field trial. Final enclosure, electrical-safety, EMC, and radio evidence must correspond to the supplied configuration. Water savings, nutrient-loss changes, and crop response depend on the site and must be established through monitored operation rather than guaranteed from the controller specifications.