Overview
The RC-PWS-600 Orchard Plant Water Stress Monitoring Station is an engineered-to-order solution from REDCOAST.LTD for growers, irrigation districts, agricultural estates, research farms, and irrigation integrators managing remote orchard blocks. It combines continuous trunk-diameter measurements, non-contact canopy temperature, local microclimate, a Web management platform, and a mobile App to show how representative trees respond before and after irrigation. Its purpose is to help operators investigate insufficient overnight recovery, excessive daytime shrinkage, and persistent canopy warming alongside existing soil and irrigation records. The reference configuration uses solar and battery power because its intended installation point has no accessible electrical supply; the station measures plant response and does not supply pumping energy.
Key Features
- Four representative trees per station: Four sealed dendrometers track diameter changes independently, allowing operators to compare individual trees before interpreting a block-level trend.
- Two canopy-temperature views: Two infrared radiometers observe selected canopy areas, reducing dependence on one viewing direction and retaining separate readings for quality review.
- Weather-aware interpretation: Air temperature, relative humidity, solar irradiance, and wind measurements provide context for canopy heating and atmospheric evaporative demand.
- Transparent stress indicators: Maximum daily shrinkage, overnight diameter recovery, canopy-to-air temperature difference, and vapor pressure deficit remain visible as individual measurements.
- Independent field recording: One-minute sampling and five-minute records continue during communications outages, with timestamped upload recovery when the connection returns.
- Custom board-level electronics: REDCOAST.LTD develops the acquisition, protected sensor-interface, low-power controller, and MPPT power-management PCBs around the project's measurement and installation requirements.
- Actionable maintenance information: Sensor disconnection, displacement near the end of travel, stale data, low battery, and abnormal charging behavior generate distinct maintenance events.
- Integration with existing irrigation workflows: Documented data exports and interfaces let operators compare plant response with irrigation events while retaining their existing controller and agronomic approval process.
Technical Architecture
The reference package includes four sealed linear dendrometers, two infrared radiometers, a shielded temperature/humidity probe, a pyranometer, a low-power wind sensor, and one field logger with an off-grid power assembly. Each dendrometer measures movement across a selected trunk diameter rather than the absolute diameter of the whole tree. An 11 mm displacement stroke accommodates seasonal movement and growth until mechanical readjustment is needed; the mounting frame fits trunks from 30 to 200 mm. This is a commercially established sensor format, as illustrated by the ECOMATIK DD-L manufacturer specifications. The specified 1 micrometer logging increment is a resolution target, not a claim of 1 micrometer absolute field accuracy.
Inside the enclosure, a custom acquisition PCB provides stable excitation, four differential analog inputs, a nominal 24-bit converter, input filtering, and cable-fault diagnostics. Separate SDI-12 and isolated RS-485 interfaces acquire digital environmental measurements, while the controller attaches sensor identifiers, calibration coefficients, timestamps, and quality flags. Sensor heads are selected from qualified measurement components; REDCOAST.LTD designs the board-level acquisition and power hardware, firmware, enclosure wiring, and application software. Raw values and derived records are stored locally before transmission, so a cloud outage does not erase the observation history.
At the edge, the station calculates daily trunk shrinkage and recovery, canopy-to-air temperature difference, and atmospheric vapor pressure deficit. The platform compares each tree against its own commissioning baseline and overlays irrigation events, rainfall where measured, and operator notes. A crop water stress index is an optional commissioned calculation: its wet and dry reference boundaries must be established for the crop, canopy geometry, and weather regime, and unsuitable observations are flagged. Trunk movement does not directly measure stem water potential in MPa, and canopy warming can also reflect radiation, wind, disease, or salinity. The system therefore provides evidence for an irrigation decision rather than presenting every threshold crossing as proof that more water is required.
Connectivity & Power
Choose LTE-M or LTE Cat 1 bis for sites with suitable cellular coverage, using an antenna and modem variant matched to the local network. LoRaWAN Class A is an alternative where a surveyed farm network already exists; it requires a gateway and network service, with the lawful channel plan selected for the installation. The gateway's power budget is separate from this station. Local SDI-12 and RS-485 connections serve nearby sensors; standard analog dendrometer leads are 5 m, with engineered shielded extensions up to 20 m for the reference configuration. More distant sample trees normally require another station rather than long, exposed analog wiring.
The standard energy package is an 80 Wp photovoltaic module, a 12.8 V 30 Ah LiFePO4 battery, and a 10 A MPPT controller. The design budget is 2 W average, or 48 Wh per day, for the specified sensors, one-minute sampling, and fifteen-minute uploads; radio transmission can briefly draw more power. At 20 degrees Celsius, a new fully charged battery provides approximately 276 Wh after allowing 80% depth of discharge and 90% downstream efficiency, equivalent to about 5.8 days at that load. The published planning autonomy is therefore five sunless days under those conditions. With two equivalent peak-sun hours and a 70% combined harvest allowance, the panel yields approximately 112 Wh per day; prolonged shading, winter irradiation, cold batteries, and repeated cellular retries require a revised energy budget.
Battery charging is inhibited below 0 degrees Celsius and above 45 degrees Celsius at the cell sensor; battery temperature and state of charge are reported separately. The reference package has no battery heater, and its five-day figure does not apply throughout the full environmental range. Persistent freezing conditions require a separately engineered thermal and energy package. Pump motors, solenoid valves, and LoRaWAN gateways are outside the station's energy allowance.
Protection & Reliability
The electronics enclosure is specified to an IP66 design target with bottom cable entries, sealed connectors, a pressure-equalizing membrane, and a separate external sun shield. Steel mast and support parts receive hot-dip galvanizing followed by a smooth matte powder-coated finish; the aluminum cabinet uses a smooth protective coating rather than an exposed zinc appearance. Conformal coating, replaceable cable protection, strain relief, and segregated battery connections address condensation, insects, dust, and field handling. The assembled configuration must be verified with its actual glands and connectors; an enclosure rating does not make exposed optical windows immune to dirt or condensation.
The reference system operates from -20 to +55 degrees Celsius, subject to the battery charging limits and sensor-specific measurement limits. Coastal or chemically exposed sites require selected sealed probes, compatible fasteners, and a project-specific coating specification; no universal salt-spray lifetime is implied. Mast foundations and panel brackets are sized from local wind loads and soil conditions. Scheduled lens cleaning, checking tree-mounted sensors as trunks grow, and reviewing battery capacity are part of the maintenance plan. Warranty scope, sensor recalibration, battery coverage, and spare-part availability are itemized in the supply agreement.
Application Scenarios
- Remote drip-irrigated fruit orchards: Install a station among representative trees in a hydraulically and agronomically consistent block without convenient mains access. Comparing daytime shrinkage with overnight recovery helps staff identify blocks needing closer irrigation inspection.
- Vineyard irrigation management: Fit appropriately sized dendrometers to representative vines and aim the infrared sensors at foliage rather than exposed soil or trellis wire. Agronomists can compare plant-response trends across approved irrigation strategies and growth stages.
- Nut orchards with contrasting soils: Place separate stations in management zones with different soil depth, rootstock, or irrigation performance. The resulting records help determine whether a single schedule produces uneven plant responses across the property.
- Water-allocation demonstration plots: Irrigation districts and agricultural service teams can instrument selected plots to compare applied-water records with plant behavior. Reports retain the measurement conditions and intervention history, supporting evaluation without promising a universal water-saving percentage.
- Outdoor perennial-crop trials: Research farms can combine the station's continuous records with periodic pressure-chamber observations and independent soil measurements. Exported data support calibration of crop-specific indicators and assessment of sensor placement.
Case-style Examples
The following are illustrative configuration examples, not claims of completed REDCOAST.LTD installations.
Orchard block with weak overnight recovery: An operator receives normal soil-moisture readings but observes uneven tree vigor near the end of a drip lateral. One RC-PWS-600 monitors four representative trees, two canopy views, and local weather; the platform imports irrigation timestamps from the existing controller. Repeated poor recovery prompts a field inspection of emitters and distribution pressure. After maintenance, the team compares subsequent recovery under similar weather, creating a documented check of the intervention rather than assuming the sensor identifies a blockage directly.
Vineyard with an existing farm radio network: A vineyard wants continuous plant-response records on a remote slope with no electrical connection. A LoRaWAN version sends fifteen-minute summaries through the existing gateway, while the station retains five-minute records locally. Small-trunk mounting frames and carefully selected canopy sightlines suit the vines. The operator receives comparable observations from different management zones and can defer schedule changes until an agronomist reviews the measurements.
Irrigation trial comparing two schedules: A research farm installs two stations, one in each matched treatment block, with the same sensor geometry and calibration procedures. Independent water meters provide applied-volume data, while periodic reference measurements help interpret the dendrometer and thermal signals. The resulting dataset allows the team to compare recovery, growth-stage response, and water application; yield or water-saving conclusions require the actual trial results.
Customization & Selection Guide
Start with the crop, trunk diameter, expected seasonal growth, irrigation layout, soil variability, and the decision the operator needs to make. The reference package measures four nearby trees; it does not imply that four trees represent any fixed number of hectares. Divide heterogeneous land into management zones and select representative, healthy trees with local agronomic input. Avoid perimeter trees or unusual canopy exposure unless these are the explicit subject of the study.
For tighter budgets, a two-dendrometer and one-radiometer package retains the same software workflow with reduced spatial replication. For rapid growth, choose a 25 mm displacement sensor and an appropriate frame, then confirm its calibrated response and logging resolution. Extended stroke is different from maximum supported trunk diameter. Wider trees may need a different measurement geometry and cannot be accommodated simply by changing the software range.
For thermal measurements, choose viewing distance and field of view together. A 36-degree full-angle circular field of view covers approximately 0.65 m across at 1 m normal distance, so sparse foliage can admit substantial soil background. Reposition the sensor or select narrower optics, and review the sightline after pruning and seasonal growth. Infrared radiometers measure a spatially averaged surface temperature rather than a thermal image; their field-of-view and calibration behavior are described in the Apogee infrared radiometer specifications.
Agree on baseline collection, alarm persistence, and the valid weather window before enabling decision alerts. A practical initial baseline period is 14–28 days, extended when representative irrigation and weather conditions have not occurred. Research published in 2025 demonstrates the usefulness of dendrometer-based orchard irrigation, but its measured outcomes belong to the study conditions and are not performance guarantees for this station. See the 2025 Agricultural Water Management study.
Deployment & After-sales
A deployment survey records cellular or LoRaWAN coverage, solar shading through the season, representative trees, machinery routes, and mounting locations. Install the mast on a suitable ground anchor or foundation, keep the photovoltaic panel outside the measurement sightlines, and route cables clear of harvesting and spraying equipment. Commissioning includes checking dendrometer travel, recording sensor orientation, verifying time synchronization, and establishing local logging before communications are enabled. The handover package includes wiring drawings, sensor assignments, calibration records for supplied probes, maintenance instructions, and a platform walkthrough.
For planning, allow 8–12 weeks for a first engineered batch after specification approval and component availability review; new PCB development, field validation, or external laboratory testing may extend this period. The confirmed schedule is issued with the project quotation. Remote diagnostics expose battery history, communications quality, missing measurements, and firmware versions. Service options include replacement sensor heads, recalibration coordination, firmware maintenance, and a quoted 24-month equipment warranty, with consumables and battery terms stated separately.
Standards & Compliance
Specifications on this page define a reference engineering configuration and procurement targets; final acceptance limits are established in the project datasheet and verified on the supplied configuration. The enclosure test basis is IEC 60529, and the EMC assessment for the measurement and control electronics is planned against IEC 61326-1. Battery selection and verification consider IEC 62619, with the transport test summary identified for the actual shipped battery type under UN battery transport provisions.
Radio variants, antenna combinations, and operating channels are selected for the installation jurisdiction. LoRaWAN channel planning follows the applicable LoRa Alliance Regional Parameters. CE documentation, RoHS material declarations, and other required market-access documentation are specified in the order and supported by the relevant assessment. These references describe the compliance pathway and do not assert existing certification of every customized configuration.
Why REDCOAST.LTD
REDCOAST.LTD delivers the complete field-monitoring solution: equipment, Web platform, mobile App, data interfaces, commissioning documentation, and ongoing technical support. Its in-house PCB and board-level design capability makes it possible to change excitation circuits, analog front ends, connector layouts, radio interfaces, low-power behavior, and solar charging electronics for a defined project. This gives procurement teams a product architecture that can be adapted to their sensors and operating practices while maintaining one coordinated hardware and software delivery.
Send REDCOAST.LTD your crop, trunk sizes, block layout, irrigation records, communications coverage, and site climate to request a customized RC-PWS-600 configuration and project quotation.
Specifications
Plant Measurement
- Dendrometer Channels
- 4 independent sealed linear sensors
- Dendrometer Displacement Range
- 0–11 per sensor; mechanical readjustment required as growth consumes travel mm
- Reference Trunk Diameter
- 30–200 with correctly sized mounting frames mm
- Dendrometer Logging Resolution
- 1; resolution is not absolute field accuracy µm
- Dendrometer Nonlinearity Target
- ≤1 of full scale; calibration and mounting errors assessed separately % FS
- Infrared Radiometer Quantity
- 2 independent canopy views
- Infrared Spectral Band
- 8–14 µm
- Infrared Field of View
- 36 full angle; 18 half-angle, circular degrees
Thermal & Microclimate Measurement
- Canopy Temperature Range
- -20 to +65 °C
- Radiometer Calibration Uncertainty Target
- ±0.3 from 0 to +50; target-to-detector difference ≤20; excludes field emissivity and background errors °C
- Air Temperature Range and Accuracy
- -20 to +60; ±0.3 from 0 to +50 under calibrated conditions °C
- Relative Humidity Range and Accuracy
- 0–100; ±2 percentage points at 20–80 and +20 °C % RH
- Solar Irradiance Range
- 0–1750; calibration uncertainty target ±5% under reference conditions W/m²
- Wind Speed Range and Accuracy
- 0–50; ±0.5 m/s or ±5% of reading, whichever is greater m/s
- Optional Rain Gauge Resolution
- 0.2 per tip; unheated mm
Acquisition & Edge Processing
- Analog Acquisition
- 4 differential inputs; nominal 24-bit ADC; 2.5 V switched ratiometric excitation
- Sampling Interval
- 60 default; 10–300 configurable s
- Stored Record Interval
- 5 default; 1–60 configurable min
- Upload Interval
- 15 default; 5–60 subject to radio airtime and energy budget min
- Local Flash Storage
- 128; at least 180 days for 32 numeric channels plus quality flags at 5-minute intervals MB
- Dendrometer Cable Length
- 5 standard; engineered shielded extensions up to 20 m
- Derived Indicators
- Daily shrinkage, overnight recovery, canopy-air temperature difference, vapor pressure deficit; CWSI after site calibration
- Alarm Persistence
- 15–180 for configured instantaneous thresholds; daily evaluation for daily indicators min
Communications & Interfaces
- Cellular Backhaul Options
- LTE-M or LTE Cat 1 bis; network-specific modem and antenna
- Farm Network Alternative
- LoRaWAN Class A; external gateway and network service required
- LoRaWAN Channel Plan Options
- EU868, US915, AU915, AS923; select lawful local variant
- Digital Sensor Bus
- 1 SDI-12 bus; up to 8 addressed low-power sensors within approved loading
- Serial Interface
- 1 isolated RS-485 port; Modbus RTU; 9600–115200 bit/s
- Pulse and Status Inputs
- 2 dry-contact inputs; pulse counting 0–100 Hz
- IP Data Transport
- MQTT or HTTPS with TLS 1.2/1.3 on cellular or gateway IP connection
- Local Service Interface
- USB-C configuration and record download; inside sealed cabinet
Off-grid Power
- Photovoltaic Module
- 80 standard; 120 or 160 with revised bracket and energy design Wp
- Battery
- LiFePO4, 12.8 V, 30 Ah; 384 Wh nominal; protected replaceable pack
- Solar Charge Controller
- MPPT; 10 A maximum battery charge current; 50 V absolute maximum PV open-circuit voltage
- Average Load Design Budget
- 2 with reference sensors, 60-second sampling and 15-minute uploads; no heater W
- Short-duration Peak Load Allowance
- 15 during communications and sensor activity W
- Daily Energy Budget
- 48 at 2 W average; excludes pumps, valves and external gateway Wh/day
- Sunless Autonomy Planning Value
- 5 at +20 °C, new fully charged battery, 80% depth of discharge and 90% downstream efficiency days
- Battery Charging Window
- 0 to +45 cell temperature; charging inhibited outside this range °C
Protection & Mechanical
- Electronics Enclosure Protection
- IP66 design target; verify complete assembly with installed glands
- System Ambient Operating Range
- -20 to +55; subject to charging limits and sensor measurement limits °C
- Cabinet Internal Humidity
- 5–95, non-condensing % RH
- External Connector Protection
- IP67 minimum when correctly mated; sensor-specific limits apply
- Cabinet Dimensions
- 400 × 300 × 180, height × width × depth, excluding sun shield mm
- Reference Mast Height
- 3; optional 4 after structural and canopy review m
- Surface Treatment
- Steel mast: hot-dip galvanizing plus smooth matte powder coating; aluminum cabinet: pretreatment plus smooth matte powder coating
- Standard Finish
- RAL 7016 mast and supports; RAL 7035 cabinet and sun shield
Platform & Delivery
- User Interfaces
- Web dashboard and mobile App; station map, tree trends, alarms and maintenance records
- Account Roles
- Viewer, Operator, Administrator
- Data Export
- CSV and JSON; documented REST API
- Cloud Record Retention Option
- 24 or 36 under the selected service agreement months
- Initial Baseline Period
- 14–28; extend until representative irrigation and weather conditions occur days
- Equipment Warranty Option
- 24 under quoted terms; battery, consumables and recalibration scope stated separately months
Capabilities — configurable per project
Specifications are tailored to each project — the options below show what we can support.
Plant Sampling Package
- 2 dendrometers + 1 infrared radiometer
- 4 dendrometers + 2 infrared radiometers
- 8 dendrometers + 4 infrared radiometers across two stations
Dendrometer Geometry
- 30–200 mm trunk frames with 11 mm stroke
- 5–50 mm vine or young-tree frames with 11 mm stroke
- 30–300 mm trunk frames with 25 mm stroke and revised calibration
Communications Architecture
- LTE-M direct-to-platform
- LTE Cat 1 bis direct-to-platform
- LoRaWAN Class A through an existing farm gateway
Site Energy Package
- 80 Wp PV + 12.8 V 30 Ah LiFePO4
- 120 Wp PV + 12.8 V 50 Ah LiFePO4 with revised enclosure
- 160 Wp PV + 12.8 V 60 Ah LiFePO4, 20 A MPPT and enlarged enclosure
Agronomic Workflow
- Plant-response trends and quality-controlled alerts
- Irrigation-event import and comparative reports
- Site-calibrated CWSI with validated wet/dry baselines
- Customer-hosted platform with documented API
Related solution guidance
Environmental Monitoring
Deploy environmental monitoring stations with sensors, solar power, gateways, dashboards, alarms and data integration for city and industrial sites.
Ports and Logistics
Outdoor IoT infrastructure for ports, yards and logistics areas: lighting, guidance, safety, solar power, monitoring and maintenance visibility.
Solar IoT Guide
A design guide for solar-powered outdoor IoT: load calculation, battery autonomy, low-power firmware, telemetry and maintenance planning.
Frequently Asked Questions
What does a plant water stress monitoring station measure?
The RC-PWS-600 measures trunk-diameter changes, canopy surface temperature, air temperature, humidity, solar irradiance, and wind. It derives daily shrinkage, overnight recovery, canopy-to-air temperature difference, and vapor pressure deficit. These indicators help interpret plant response alongside irrigation records; they do not directly measure stem water potential or establish the cause of stress.
How is this different from a soil moisture sensor or irrigation controller?
A soil sensor describes conditions at its installation depth, while a dendrometer and canopy radiometer observe the plant's response to its environment. The RC-PWS-600 adds this plant-response layer to an existing irrigation system and does not include pump or valve power outputs. Combining plant data with soil observations and applied-water records helps operators investigate disagreements before changing a schedule.
Does the station automatically calculate a reliable crop water stress index?
The optional CWSI calculation requires suitable canopy views and locally validated wet and dry reference boundaries for the crop and weather regime. Until that commissioning is complete, the system presents measured temperatures and other indicators without treating a generic index threshold as an irrigation command. Wet foliage, mixed soil backgrounds, changing sunlight, and unsuitable wind conditions can invalidate an observation.
How many trees or hectares can one station represent?
The reference package measures four trees and two canopy views, with 5 m standard dendrometer cables and engineered extensions up to 20 m. There is no universal hectare coverage because soil, irrigation hydraulics, rootstock, crop age, and exposure affect representativeness. Use separate stations for distinct management zones and select trees with agronomic guidance.
How long will the station work without sunshine?
The reference 12.8 V 30 Ah battery contains 384 Wh nominal energy. At 20 °C, allowing 80% depth of discharge and 90% downstream efficiency gives approximately 276 Wh, or 5.8 days at a 48 Wh daily load; the planning specification is five days. Cold, aging, poor cellular coverage, and added equipment reduce this duration, and battery charging is disabled below 0 °C or above 45 °C.
Can it operate without cellular coverage?
A LoRaWAN version can use a surveyed farm gateway with its own network backhaul and power supply. If neither cellular nor gateway connectivity is available, local recording continues and records can be retrieved through the internal service port, but remote alerts are unavailable during that interval. Cloud dashboards identify stale data rather than presenting old measurements as current.
Can REDCOAST.LTD develop custom hardware for our sensors and platform?
Yes. REDCOAST.LTD can develop new acquisition, interface, controller, and power-management PCBs, together with firmware, the Web platform, and mobile App workflows. Custom work can change sensor excitation, input ranges, connectors, communications, and enclosure arrangements; sensor calibration and system verification are included in the project scope definition.
Are water savings, field accuracy, and certifications guaranteed?
Water savings depend on the starting irrigation practice, crop, weather, and subsequent management decisions, so no fixed saving is promised. The 1 µm dendrometer logging increment is not 1 µm absolute accuracy, and infrared calibration uncertainty excludes field-of-view and emissivity errors. The listed standards are assessment and procurement targets; verified performance, test reports, and market-access documentation must correspond to the final supplied configuration.